General characteristics
Operating temperature (°C)-20®+80
 20®+60 (90-140 V AC)
Storage temperature (0C)-40®+100
Input-to-Output isolation voltage (Vrms)2800
Input/Output to ground isolation voltage (Vrms)2500
Operating frequency (Hz)47®63
Housing materialUL-94V0 Self extinguishing polycarbonate
Heatsink materialAnodized aluminum black
Protection (IEC 60529) - CasingIP 20
Weight (g)200
Altitude for nominal performance (/sea level)2000 m
Input terminal capacity (stranded and solid wire)16 AWG ®24 AWG
Input terminal tightening torque (Nm)0.5
Min. output terminal capacity (IEC 941-1)16 AWG
Max. output terminal capacity (IEC 941-1) stranded wire8 AWG
Max. output terminal capacity (IEC 941-1) solid wire10 AWG
Output terminal tightening torque (Nm)1.3
Maximum cross section for output wire (mm2)10
Safety standards
Conformity to standardsIEC 62314
IEC 60947-4-3 (AC 51)
CE compliant with LVD 73/23/EEC
TUV certified per EN 60950
CSA recognized per C22.2.no. 14-95
UL recognized per UL 508
Vibrations according to IEC/EN60068-2-635 mm / 10-55 Hz
Shock test IEC 60068-2-2715 G / 11 ms
Immunity to electrostatic discharges acc. IEC/EN 61000-4-2Level 3
Immunity to electrostatic fields acc. ENV 50140/204 (IEC 1000-4-3)Level 3
Immunity to rapid transient bursts acc. to IEC 1000-4-4Level 3
Immunity to shock waves according to IEC/EN 61000-4-5Level 3
Immunity to radio frequency in common mode acc. to ENV (CEI 1000-4-6)Level 3
Conducted and radiated noise for industrial environnements per CISPR 11Class A
PollutionDegree 2
OvervoltageCategory III
Comments
For multiple unit configuration consult our website www.crouzet.com/cooltech.
Relay style SSR's @280 V AC @60 C require #20 Control Wire.
LED is not an absolute indicator of power being present.
Relay output characteristics
Voltage range (Vrms max)24-28024-280
Non-rep. peak voltage (Vpeak)550550
Maximum off-state leakage at Vmax and T = 25 °C (µAeff per phase)1414
Current max @ 25°C (A)1020
Current max @ 40°C (A)1020
Minimum current (mArms)100100
On-state voltage drop at I max (Vpeak)1.21.35
I2t (t = 10 ms) (A2s) (50 - 60 Hz)340 - 280750-600
Static dv/dt (V/µs)500500
Utilization category AC 51 (A)1020
Max. non-rep. 1 s surge (T=25°C) (A)30145
Max. non-rep.1-cycle surge (T=25°C) (A)100400
Inputs specifications
Input voltage (V)4-32 V DC90-140 V AC180-280 V AC
Turn-off voltage (V)11010
Max. controled current (mA)1068
Min. input current (mA)856
Turn-on time (ms) (zero voltage relay)8.33 (60Hz) - 10 (50Hz)2020
Max. turn-off time (ms)8.33 (60Hz) - 10 (50Hz)3030